How do I upgrade from Lookout 6.5 to 6.7
I am trying to upgrade from 6.5 to 6.7. When I try to do this it wants to do a full install.Is there a way just to do the upgrade?
View Articlematerial testing
Is there anyone need mateiral testing instrument such as Universal testing machine, impact testing machine, compression testing machine etc?
View ArticleLookout 6.6 - Recommended Active X Control Not Working in Web Client
I am runnning Lookout 6.6, and I created some Adobe Reader Active X controls so users could view pdf files from within Lookout. It is working fine on the client verison, but when I went to export the...
View Articledelete state file when logging out of lookout 6.6
using lookout 6.6, 5800 I/O points. need to delete state file from client stations when logging out of lookout.
View ArticleLookout 6.0 opc/opl error
I have lookout version 6.0 and RSLINX 2.43 OEM installed. I can see the plc's through RSLINX but Lookout is giving me red "X" for all the data display windows. I am running Windows 32bit XP. any...
View ArticleModbus Com driver lost after timeout
LO 6.6 running on Win XP We have 5 RTUs running over a slow radio linkage. All works OK until there is a radio timeout or other com glitch. The modbus begins normal polls and sometimes recovers OK,...
View Article30 day rolling average of a single variable based on 1 hour averages?
Can anyone recommend the best way to keep a 30 day rolling average of a single variable based on 1 hour averages? I am thinking about using Citadel with and SQL query to update the average. If...
View ArticleLookout 6.02 installation for Windows 7
Recently, my company required the installation of win7 from xp. After the installation I attempted install Lookout 6.02 but once installed it will not open and keeps giving me a time server error....
View ArticleOPC lookout server ver. 5.1
I'm seeing the following error message-2147352566 (8002000A) Out of Present Range Can you find out what the issue is? How do we resolve this error?
View ArticleDynamic Text Signals
Hi I want to have Dynamic Text in my project as i saw the "Lookout Developer’s Manual" chapter 6 the way to do this is insert Expression and in the yellow field using choose Expression . i select...
View ArticleLookout 3.8.13 poll rate issue
We recently added ~ 30 tags to our existing Lookout 3.8.13 application and observed noticeable delays in the poll rate. Even though we set the poll rate to 1s (0:01) we observed the actual watchdog...
View ArticleLookout V3.8 to 6.7 --> .lks (1142) error: Syntax error
Hello, I have a problem after converting an application from lookout version 3.8 to 6.7. It says compile error:...\Version Actuelle\usinemixdec2010.lks(1142): error: Syntax error I've got 5 errors...
View ArticleChange Administrator Account Password in Lookout V 6.7
I have recently installed Lookout for Win32, Version 6.7 (build 49153) on my work computer. My work computer is a Windows 7, 64 bit operating system, Service Pack 1. When I try to change the...
View ArticleExpression or Calculation tag value are reset to last application saved value...
I'm doing daily logging data for daily report and for the daily flow calculation, I'm doing those step: 1- When Timer1 = 11h55 -> Daily_Volume = (Actual_Volume - Yesterday_Volume)2- When Timer2 =...
View ArticleUsing pots why can't you have a fraction decimal for value i.e.. 1.5 rounds...
When creating pots why can't a decimal be entered for a value i.e.. 1.5 you can define the range i.e.. 1-30 but you cannot enter a decimal value without being rounded up to a whole number???
View Articlewhen creating a remote address in a pot or other objects you cannot use a /...
when creating a remote address in a pot or other objects you cannot use a / for a address??? my ladders addresses contain such ////// symbols for some addresses???
View Articlewhat object would i create to have two addresses i.e. plant 1 auto Remote-...
what object would i create to have two addresses i.e. plant 1 auto Remote- ab1.n10:0_1 plant 1 stop Remote - ab1.b3_26 ???
View ArticleI am not able to get my app to talk to a CTI 2500-C400 CPU.
I am not able to get my application to talk to a CTI 2500-C400 CPU. I need help getting communications initiated. Can you please help!
View Article6.0.2
We have look out 6.0.2 and i am sure it is not supported by windows 7. If we install the new version that is supported by windows 7 Is it a free upgrade or there is a cost associated with that? Which...
View Article