Lookout / Motorola FEP/1000 RTU.  Has anyone worked with the ACE1000 and counter input's we are new to Motorola ACE-1000 product. We have a couple systems deployedhowever have not worked with any...

View Article


reconocimiento de proyecto en lookout v6.7.1

hola buen dia a todos, tengo una situacion y me enviaron a esta liga lo que sucede es que se esta haciendo la migracion de un proyecto, este proyecto esta en lookout, se compro el software lookout...

View Article


Lookout 6.6 server/client process not working across network

I have a server and client process setup in Lookout 6.6 using a symbolic link in the client process for all of my data members, switches, etc.  If I have the client process running on the same PC as...

View Article

Lookout 6.1, Modbus Protocol Statistics

Under "Options" - "Modbus" - "Statistics", what does all this information mean. We have been getting a lot of "Response too short" and "No response" errors. Just trying to figure out what all these...

View Article

Trends stopped working

Can anyone tell me what would cause all trends to stop after a lookout 6.6 process has been running for years and trending fine?

View Article


How to change a value based on the time?

Using Lookout 4.01: Is it possible to set the value of a gauge or pot based on the system time? Starting at midnight with value 0%, then increment the value each hour (on the hour) to 100% at midday...

View Article

Lookout 6.7.1 not connecting to GE 90-30 PLC

We have Lookout 6.7.1 running on a Windows 10 PC, trying to connect to a GE Fanuc 90-30 PLC.  The PLC software (VersaPro) connects to the PLC in a XP virtual machine, but Lookout running in the (Win10)...

View Article

Image may be NSFW.
Clik here to view.

Clients losing connection to server

This issues has been happening about once a week, my clients are losing connection to my server randomly at any time. When i view the client connection monitor, my list is blank. Sometimes when i open...

View Article


Mailer object stops after two tries

I am trying to create a mailer object that sends out emails but it stops after sending it two times. Please help. I am using Lookout for Win32 Version 6.7 (build 49153)Mailer Object:Name:...

View Article


Getting 50 points from 10 points

I I'm having a IV curve their points are max 20 and I wanted to expand the points in more than 20 points, having same curve.Can someone please help me with that

View Article

PLAYWAVE

I have a strange problem that I can not seem to figure out. We are using National Instruments Lookout for WIN32 Version 6.7.1 Build 49152. We have always used Playwaves to play recorded DTMF tones to...

View Article

Lookout feezing when com ports become unavailable

Hello,I am running Lookout v6.7.1. lookout is controlling 30 temperature controllers on 8 virtual com ports using Modbus. When the power to the temperature controllers is lost there are many alarms...

View Article

I need to know if Lookout 6.7.1 uses Microsoft SQL for it's Database.

My IT Department is asking if the Lookout is using a SQL Database that they can backup using simple SQL Queries. What should I tell them?  Thanks 

View Article


I need to program a pulse on time of day

I am needing to send a pulse out of the HMI ever morning at 02:05 ( 2:05 am) using the PC clock to the PLC clock.  Wanting to synchronize the PC and PLC clocks.

View Article

Status of a counter in a DirectLogic PLC

The previous lookout I used you simply created an expression that read: "DL240.CT2A" for example to look at CNT2 in the PLC using a serial port connection.Now Lookout says "Not a member of class DL205:...

View Article


LookOut 6.5 - server - client communication

I am using LookOut 6.5 already couple years. Recently I noticed a problem which was not expected at all.  There are three clients installed on Win7.  There are8   Hitachi  PLCs communicating with...

View Article

Upgrade LookOut 6.5 to 6.7

What is the cost of upgrading LookOut 6.5 to  6.7?What are the significient changes?What  are the requests for Server and Client computers?

View Article


Lookout server modbus data collection question

Is there any way to determine how many bytes of data I am polling over an individual Modbus station in a month time frame? Can I run it through the Modbus statistics and calculate?

View Article

Direct logic driver addressing to Modbus addressing

Hi  I have an older Lookout Direct 4.X system that needed to be updated. We have purchased a new Windows 10 computer and Lookout 6.7.1. My original system uses the Direct Plus driver to talk with the...

View Article

Citadel Logging Frequency Limitation in Lookout 6.5 and 6.7.1

Usually, I don't push Lookout for data acquisition beyond once per second.  Recently, I had a request to push a Modbus TCP device communication with Lookout to as fast as possible.  I was able to get...

View Article